HeatingCodes

Takagi tankless error codes (T-KJr2, T-K4, T-D2)

These Takagi heaters report faults as a number on the remote controller, as a 7-segment display on the T-D2, or as a number of red LED flashes on the T-KJr2 and T-K4 board.

What this table coversError codes from the Takagi/A.O. Smith troubleshooting guide for the non-condensing T-KJr2 (110), T-K4 (310) and T-D2 (510) tankless water heaters. Condensing and newer Takagi models have different guides.

How to read the display

On the T-KJr2 and T-K4 the remote controller shows a two-digit code and the red LED on the board flashes a count that points to the same fault. On the T-D2 the board display and remote show a three-digit code (for example 111 instead of 11). The table gives both. Note that the LED count is not unique: Takagi lists three flashes for both ignition failure (11) and flame loss (12).

Takagi says to contact its technical service department for several of these problems, and to have the gas supply and manifold pressure checked by a qualified person.

Takagi code table

CodeMeaningWhat the document says
03 (031) Incorrect dipswitch settings Gas type is a common dipswitch error. LED: 1 flash.
10 (101) Warning for the 99 error code (abnormal combustion) LED: 5 flashes. Full explanation
11 (111) Ignition failure The heater did not fire after three attempts. LED: 3 flashes. Full explanation
12 (121) Flame loss Flames disappeared while the unit was supposed to be running. LED: 3 flashes. Full explanation
31 (311) Output thermistor LED: 2 flashes.
32 (321) Inlet thermistor LED: 2 flashes.
39 (391) Air-fuel ratio rod failure LED: 2 flashes.
51 (510) Abnormal gas valves LED: 6 flashes.
55 Abnormal solenoid gas valve LED: 6 flashes.
61 (611) Abnormal fan motor LED: 4 flashes.
70 (701) Computer board fault LED: 1 flash.
72 (721) False flame detection LED: 6 flashes.
74 (741) Remote controller communication failure
99 (991) Abnormal combustion Refer to error code 101 (10). LED: 5 flashes. Full explanation

Source: Takagi 321923-000 troubleshooting guide, Table 2 (Error Codes). Code format is T-KJr2/T-K4 remote code, then the T-D2 code.

Detailed explanations

SafetyThese tables describe what the manufacturer documents say. Gas, combustion, refrigerant and line-voltage repairs are for licensed professionals. If you smell gas, leave the building and call your gas utility or 911. Safety disclaimer.

Sources