Mitsubishi Electric mini-split error codes
Mitsubishi Electric wall-mounted mini-splits report faults in more than one way, and the method depends on the series. On MSZ-GX units you read a two-character code from the wireless remote while the indoor operation-indicator lamp is blinking. On MSZ-FH, MSZ-FS and MSZ-GL / MSY-GL units the service manuals tell you to count flashes of that same lamp. The tables below keep those two methods separate and say which series each row comes from.
How to read the display
MSZ-GX letter codes: with the remote off, point it at the indoor unit and hold CHECK with a fine-tipped object until the indoor unit beeps and the remote shows 00. Press the up or down buttons to step through codes. Two beeps means the unit has the error for the code shown; one beep means no error for that code; no beep means the diagnosis failed, so try again. The manual says to stop using the air conditioner, turn off the breaker and contact your dealer when the unit has an error. Pressing other buttons cancels the display. If the remote is operated while the lamp is not blinking, the code shown might not be accurate.
MSZ-FH, MSZ-FS and MSZ-GL / MSY-GL flash counts: count flashes of the left or upper OPERATION INDICATOR lamp. A steady rapid blink (0.5 seconds on, 0.5 seconds off) is one pattern. The numbered patterns flash that many times and then stay off for 2.5 seconds before repeating. The service manuals say to check at least two consecutive cycles. These series also have a separate "failure mode recall" function whose flash counts do not match the table below; the comparison table is the ordinary troubleshooting check table (section 9-4), not the recall table. A longer walkthrough for the GL lamp is on this site's MSZ/MSY-GL blinking light page.
Mitsubishi Electric code table
| Code | Meaning | Applies to | What the document says |
|---|---|---|---|
| E6 / E7 | Indoor unit: serial signal | MSZ-GX / MUZ-GX (A2L), operation manual En-18 | |
| EE | Indoor unit: inconsistency of the indoor unit and outdoor unit's refrigerant | MSZ-GX / MUZ-GX (A2L), operation manual En-18 | |
| Fb | Indoor unit: indoor control system | MSZ-GX / MUZ-GX (A2L), operation manual En-18 | |
| FH | Indoor unit: refrigerant sensor of the indoor unit | MSZ-GX / MUZ-GX (A2L), operation manual En-18 | |
| FL | Indoor unit: refrigerant leakage abnormality of the indoor unit; abnormality related to the refrigerant sensors for the other indoor units when multiple indoor units are connected | MSZ-GX / MUZ-GX (A2L), operation manual En-18 | |
| P1 | Indoor unit: room temperature thermistor | MSZ-GX / MUZ-GX (A2L), operation manual En-18 | |
| P2 / P9 | Indoor unit: indoor coil thermistor | MSZ-GX / MUZ-GX (A2L), operation manual En-18 | |
| P4 | Indoor unit: drain sensor | MSZ-GX / MUZ-GX (A2L), operation manual En-18 | |
| Pb | Indoor unit: indoor fan motor | MSZ-GX / MUZ-GX (A2L), operation manual En-18 | |
| E8 / E9 / EC | Outdoor unit: indoor/outdoor communication, receiving error | MSZ-GX / MUZ-GX (A2L), operation manual En-18 | |
| FC | Outdoor unit: nonvolatile memory data | MSZ-GX / MUZ-GX (A2L), operation manual En-18 | |
| Fd | Outdoor unit: different voltage | MSZ-GX / MUZ-GX (A2L), operation manual En-18 | |
| P8 | Outdoor unit: 4-way valve / pipe temperature | MSZ-GX / MUZ-GX (A2L), operation manual En-18 | |
| PL | Outdoor unit: outdoor refrigerant system | MSZ-GX / MUZ-GX (A2L), operation manual En-18 | |
| U3 | Outdoor unit: discharge temperature thermistor | MSZ-GX / MUZ-GX (A2L), operation manual En-18 | |
| U4 | Outdoor unit: defrost thermistor, fin temperature thermistor, P.C. board temperature thermistor, ambient temperature thermistor or outdoor heat exchanger temperature thermistor | MSZ-GX / MUZ-GX (A2L), operation manual En-18 | |
| UE | Outdoor unit: stop valve (closed valve) | MSZ-GX / MUZ-GX (A2L), operation manual En-18 | |
| UP | Outdoor unit: outdoor power system | MSZ-GX / MUZ-GX (A2L), operation manual En-18 |
Letter-code source: Mitsubishi Electric MSZ-GX operation manual, "Error Code Display Mode" table (page En-18). Rows are grouped as in the manual: indoor unit codes first, then outdoor unit codes. H6 is not in this GX table.
OPERATION INDICATOR flash patterns on FH, FS and GL series
The service manuals for MSZ-FH (OBH683C, section 9-4), MSZ-FS (OBH872A, section 9-4) and MSZ-GL / MSY-GL (OBH732C, section 9-4) use flash counts on the indoor OPERATION INDICATOR, not the two-character remote codes in the table above. FH and FS call the lamp the left lamp; the GL manual calls it the upper lamp. The meanings below use the manuals' wording, condensed. Where the three documents agree, the row lists all three series. Differences are called out in the last column.
| Pattern | Meaning | Applies to |
|---|---|---|
| Rapid blink (0.5 s on, 0.5 s off) | Miswiring or serial signal: the serial signal from the outdoor unit is not received for 6 minutes. | MSZ-FH (OBH683C), MSZ-FS (OBH872A), MSZ-GL / MSY-GL (OBH732C) |
| 2 flashes | Indoor coil thermistor or room temperature thermistor short or open circuit. | MSZ-FH (OBH683C), MSZ-FS (OBH872A), MSZ-GL / MSY-GL (OBH732C) |
| 3 flashes | Indoor fan motor: the rotational frequency feedback signal is not emitted during indoor fan operation. | MSZ-FH (OBH683C), MSZ-FS (OBH872A), MSZ-GL / MSY-GL (OBH732C) |
| 4 flashes | Indoor control system: the unit cannot properly read data in the nonvolatile memory of the indoor electronic control P.C. board. | MSZ-FH (OBH683C), MSZ-FS (OBH872A), MSZ-GL / MSY-GL (OBH732C) |
| 5 flashes | Outdoor power system: the compressor stops three times in a row, within 1 minute of start-up, from overcurrent protection or start-up failure protection. The indoor and outdoor units do not operate. The manuals also say to check the stop valve. | MSZ-FH (OBH683C), MSZ-FS (OBH872A), MSZ-GL / MSY-GL (OBH732C) |
| 6 flashes | Outdoor thermistors short or open circuit during compressor operation. | MSZ-FH (OBH683C), MSZ-FS (OBH872A), MSZ-GL / MSY-GL (OBH732C) |
| 7 flashes | Outdoor control system: the unit cannot properly read data in the nonvolatile memory of the inverter P.C. board or the outdoor electronic control P.C. board. | MSZ-FH (OBH683C), MSZ-FS (OBH872A), MSZ-GL / MSY-GL (OBH732C) |
| 14 flashes or more | Other abnormality: an abnormality other than the rows above is detected. All three manuals say to check the stop valve and the 4-way valve and to use the outdoor unit failure mode recall for more detail. The FS manual also lists an abnormality of the indoor thermistors, the defrost thermistor or the ambient temperature thermistor in this row. | MSZ-FH (OBH683C), MSZ-FS (OBH872A; extra thermistor wording), MSZ-GL / MSY-GL (OBH732C) |
| Left or upper lamp stays on; outdoor unit does not operate | Outdoor control system: the unit cannot properly read data in the nonvolatile memory of the inverter or outdoor electronic control P.C. board. The manuals say to check the blinking pattern of the LED on that board. | MSZ-FH (OBH683C), MSZ-FS (OBH872A), MSZ-GL / MSY-GL (OBH732C) |
| Upper lamp on, lower lamp flashing | MXZ type: the operation mode of each indoor unit is set differently to COOL (includes DRY) and HEAT. The GL manual says to unify the operation mode. | MSZ-GL / MSY-GL (OBH732C) only, in this set of manuals. Not listed in the FH or FS 9-4 tables we checked. |
For a longer GL-only walkthrough of the lamp, including the difference between the ordinary table and failure mode recall, see the MSZ/MSY-GL blinking light page.
MXZ multi-zone outdoor units
The MXZ-2C20NAHZ, MXZ-3C24NAHZ and MXZ-3C30NAHZ service manual (OBH702A) documents faults with LED1 and LED2 on the outdoor control board, not with the two-character remote codes in the first table. Indoor heads attached to an MXZ still follow that indoor unit's own lamp or remote table. If you have an MXZ outdoor unit, use OBH702A (or the edition that matches your model) together with the indoor manual.
Sources
- MSZ-GX Operation Manual, "Error Code Display Mode" (A2L series, 2024) (Mitsubishi Electric) Covers: Mitsubishi Electric MSZ-GX / MUZ-GX A2L-series wall-mounted units. Other Mitsubishi lines (for example FH, GL, GE) can use different code sets and LED blink patterns; use the manual for your exact model.
- Service Manual OBH732 Revised edition-C: MSZ-GL06NA to MSZ-GL24NA and MSY-GL09NA to MSY-GL24NA, Operation Indicator and Failure Mode Recall (Mitsubishi Electric (copy hosted by distributor Total Comfort Mechanical)) Covers: Mitsubishi MSZ-GL and MSY-GL wall-mounted indoor units (06 to 24 sizes) as listed in the manual. Other Mitsubishi lines (for example the GX/FH series) have their own tables.
- Service Manual OBH683 Revised Edition-C: MSZ-FH09NA, MSZ-FH12NA, MSZ-FH15NA and MSZ-FH18NA, section 9-4 Troubleshooting check table (Mitsubishi Electric (copy hosted by Meier Supply)) Covers: Mitsubishi Electric MSZ-FH09, FH12, FH15 and FH18 wall-mounted indoor units (Hyper-Heating indoor heads). Matching MUZ-FH outdoor units have their own outdoor service manual (OBH684).
- Service Manual OBH872 Revised Edition-A: MSZ-FS06NA to MSZ-FS18NA, section 9-4 Troubleshooting check table (Mitsubishi Electric (copy hosted by Meier Supply)) Covers: Mitsubishi Electric MSZ-FS06, FS09, FS12, FS15 and FS18 wall-mounted indoor units (U1). Matching MUZ-FS outdoor units are covered in OBH873; MXZ-C outdoor connections are covered in OBH702.
- Service Manual OBH702 Revised Edition-A: MXZ-2C20NAHZ, MXZ-3C24NAHZ and MXZ-3C30NAHZ, section 11-4 Troubleshooting check table (Mitsubishi Electric (copy hosted by Meier Supply)) Covers: Mitsubishi Electric MXZ-2C20NAHZ, MXZ-3C24NAHZ and MXZ-3C30NAHZ multi-zone outdoor units as listed in this edition of the manual. Other MXZ sizes and later revisions can differ.