HeatingCodes

Rheem and Ruud furnace codes 22 and 61: main limit open and blower fault

Short answerOn a Rheem or Ruud (-)801T furnace, code 22 means the main limit (or HALC) is open and code 61 means the blower is unable to run. If the main limit stays open for more than 150 seconds, the display alternates 61 and 22. Rheem says the control declares a dead blower and, after four tries in one heat call, goes to a hard lockout.

What the codes mean

In Rheem's fault code list for the (-)801T series, code 22 is Main limit or HALC open and code 61 is Blower fault: blower unable to run. The main limit is the temperature switch that guards against overheating. When it opens, the control stops the burners and relies on the blower to cool the heat exchanger. If the blower is not working, the limit stays open.

The 150-second rule

Rheem's description is specific. When the main limit has been open during a gas heat call for more than 150 seconds and has not yet re-closed, the display alternates codes 61 and 22 until the limit re-closes. After the main limit has been open for more than 150 seconds, the control declares a dead blower and the display alternates 61 and 10 (non-operational blower and soft lockout) during the one-hour lockout.

The control keeps trying. The dead-blower fault and its one-hour lockout can occur up to four times in a single heat call. On the fourth, the control enters a hard lockout and shows code 61. Rheem notes that this particular hard lockout can be reset by cycling the heat call, unlike the code 93 internal fault lockout.

Other limit-related codes on the same list

CodeMeaning (per Rheem)
22Main limit or HALC open
33MRLC (manual reset limit control, also called rollout) open
61Blower fault: blower unable to run
10One-hour lockout. Alternates with the cause, for example 61 and 10.
93Internal control fault (hard lockout, cannot be cleared by cycling the heat call)

The rollout code 33 is the one that deserves extra caution. A rollout limit protects against flame coming out of the burner area, and it should not be reset without understanding why it tripped. Compare Goodman EE3 and E11, where the manufacturer says the cause must be found before the switch is reset.

What to do

A limit that opens because of a dirty filter or closed registers is something a homeowner can address. A limit that opens because the blower motor, capacitor or wheel has failed is not. If the furnace shows 61, treat it as a failed blower until a technician says otherwise: you will usually notice that no air comes out of the registers at all.

Safety Never jumper, bypass or tape over a limit, rollout or pressure switch. If you smell gas, leave the house and call your gas utility from outside. If a carbon monoxide alarm sounds, get everyone outside and call 911.

Safe homeowner checks for Rheem or Ruud furnace codes 22 and 61

  1. Turn the thermostat offLet the furnace cool. The main limit re-closes when the heat exchanger cools.
  2. Replace a dirty filterA clogged filter restricts airflow and heats up the heat exchanger. Install a clean filter.
  3. Open registers and grillesMake sure supply and return registers are open and unblocked.
  4. Listen and feel for the blowerSet the thermostat to heat. If the display shows 61 and you feel no airflow at the registers, turn the furnace off and call a technician.

Frequently asked questions

Does code 61 always mean the blower motor is dead?

Rheem's definition is that the control declared a dead blower after the main limit stayed open more than 150 seconds. A failed motor is a common reason, but a technician must confirm.

What is HALC?

Rheem lists "main limit or HALC open" for code 22. The document does not spell out the abbreviation in this table, so check your furnace documentation or ask your technician.

How do I clear the 61 hard lockout?

Rheem says that lockout can be reset by cycling the heat call. That only helps once the cause is fixed. If the blower is dead, the lockout will come back.

Sources

Safety note: this page is general information drawn from the sources above. Gas, combustion and line-voltage repairs belong to a licensed professional. Your own equipment's label and manual take priority over anything here. Read the full disclaimer.